There are two vacuums used for the Desktop Metal Shop System. The Nilfisk VHC 110 and the Tiger-Vac. Both are immersion-type explosion-proof vacuums, and no other vacuums should be used for metal powder processes. Each is filled with water and used throughout the printing process.
Images by: Terrapin Works
Parts
No parts specified.
-
-
Each vacuum has a separable bottom which is filled with water
-
Take the vacuum tube out and cover the hole with the attached cover
-
To separate push the bar connected to the bottom upward and it should drop the bottom to the ground
-
On the "Tiger-Vac" there is a colander that gets stuck to the top. Pull downwards on it slowly until it comes off and sits inside the bottom
-
-
-
Roll the bottom of the vacuum to an area where it can be filled with tap water
-
Fill the tank until the meter on the side reaches the given max level
-
-
-
Roll the bottom back to the vacuum
-
Push the bottom into place making sure the two sides of the bar fit into the slots
-
Pull the bar down to bring the bottom into place
-
Make sure the seal between the top and bottom is tight
-
Take the cover off the vacuum hole and put the vacuum tube back on
-
For more information related to vacuum maintenance and cleaning, use the manuals for each vacuum. They can be found on the manufacturer websites.