Introduction
After every print the recoating roller gets powder on it and must be cleaned often.
Tools
Parts
No parts specified.
-
-
Anti-static wipes are required for this process. They are located in the Connex cabinet and are much flimsier than the Texpads
-
-
-
When prompted by the front panel, tap Start
-
Open the top cover
-
Move the fusing carriage to the center of the print area
-
-
-
Locate the metal roller underneath the left side of the fusing carriage
-
Clean the roller with an anti-static wipe dampened with IPA
-
Rotate the roller as you finish cleaning a section, to clean the entire roller
-
Do not touch the roller with your bare hands
-
Close the top cover and tap Continue, then OK on the touchpad
-